V Series
Specifications


Input
90-132 VAC or 180-264 VAC, 47-440 Hz.
Consult factory for 400 Hz. operation.

Emissions
FCC 2070 Part 15, Class A/EN 55022, Class A Conducted. EN 60 555-3/EN 61000-3-3, Voltage Fluctuations.

Immunity
EN 61000-4-2, Electrostatic Discharge.
IEC 1000-4-3, Radiated Field.
IEC 1000-4-4, Electrical Fast Transients.
EN 61000-4-5, Level 3 Surge.
IEC 1000-4-6, Conducted Field.

Input Surge
17 amps peak from cold start for models up to 250 watts or less, 68 amps for other models, from nominal 110 or 220 VAC.

Efficiency
80% typical.

Holdup Time
20 milliseconds after loss of nominal AC power.

Outputs
See table of models.

Line Regulation
±0.1% for line change from nominal to min. or max. rating with 20% min. load on the measured output. Singles to no load.

Load Regulation
5V main/singles ±0.2%
-5V aux. ±3%
±12V aux. ±2%
±15V aux. ±2%
+24V aux. ±1.5%
for load change from 60% to 20% or 100% max. rating. Singles to no load.

Cross Regulation
±0.2% for load change on the main 5V output from 75% to 50% or 100% max. rating with 20% min. load on the measured output. Not applicable to singles.

Centering
5V main/singles ±5% trim adj.
1st and 2nd aux. ±5% trim adj. tracking
3rd aux.: -5V ±3%, +12V ±2%, +24V ±1%
with all outputs loaded to 50% max. ratings and output #2 set precisely at its rated value.

Ripple & Noise
1% or 100 mV, pk.-pk., 20 MHz bandwidth.

Operating temperature
0-70°C. Derate 2.5%/°C above 50°C.

Cooling
Models

Forced Air

V120, V180, V225, V250, V270, V360

30 CFM

V325, V501, V601

60 CFM


Temperature Coefficient
5V main/singles ±0.02%/°C
Auxiliaries ±0.05%/°C

Dynamic Response
Peak transient less than ±2% or ±200 mV for step load change from 75% to 50% or 100% max. ratings.

Recovery Time
Less than 400 microseconds on main/singles output.
Less than 50 microseconds on post regulated auxiliaries.

Safety
Units Certified to UL 1950/60950, CSA 22.2 No. 60950-00, EN 60 950, IEC 950.

Dielectric Withstand
3750 VRMS input to ground.
3750 VRMS input to output.
700 VDC output to ground.

Spacing
8 mm primary to secondary.
4 mm primary to grounded circuits.

Leakage Current
0.75 mA at 115 VAC, 60 Hz. input.

AC Input Undervoltage
Proprietary proportional drive and low voltage lockout protects against damage for undervoltage operation.

Soft Start
Units have soft start feature to protect critical components.

Overvoltage Protection
Standard on main output/singles. Optional on auxiliaries.

Reverse Voltage Protection
All outputs are protected up to load ratings.

Overload
Outputs short circuit protected by current foldback with automatic recovery. Post regulators have individual current foldback protection.

Remote Sensing
On 5V main/singles which are fully isolated from all auxiliaries.

Shock
MIL-STD 810-E Method 516.4, Procedure I.

Vibration
MIL-STD 810-E Method 514.4, Category 1, Procedure I.

OPTIONS

Power Fail Monitor (Code 02)
Optional monitor provides a TTL signal 2 ms. min. prior to loss of output power with outputs fully loaded from 100VAC/200VAC line loss.

Thermal Shutdown (Code 04)
Optional circuit cuts off supply in case of local over temperature. Unit resets automatically when temperature returns to normal.

Cover (Code 08)
Optional cover for safety and EMI. Place fan for comparable flow as in uncovered units.

Inhibit (Code 16)
Optional TTL logic inhibit input.

Auto Ranger
Model AR-1 accessory provides automatic operation at specified input ranges without strapping.

*Specifications subject to change without notice.


 