V
Series
High Reliability Switchers
Models & Ratings - General Purpose Single
and Quad Output
|
|
|
|
Features
- Single and quad
output, 120-600 watts
- Ultra-low cost
open frame switchers
- Dual loop regulation
system
- Fast stock delivery
- 200K-1 million
hours MTBF
- 80% typical efficiency
|
Description
V Series World Class switching power supplies are a family of single
and quad output models designed for a wide variety of commercial and
industrial applications. These industrial workhorses have demonstrated
MTBF ratings greater than 500,000 hours. A proprietary proportional
drive circuit prevents excess switch saturation and permits higher switching
frequency operation. This makes possible increased reliability and a
compact size.
One of the unique
features of the V Series is a dual loop regulation system. This system
provides a tightly regulated main output and eliminates cross regulation
in the auxiliaries.
|
|
V
Singles
|
|
Model
|
Output
|
Max
Power
|
|
V120AXX
|
5V/25A
|
120W
|
|
V120BXX
|
12V/10A
|
120W
|
|
V120CXX
|
15V/8A
|
120W
|
|
V120DXX
|
24V/5A
|
120W
|
|
V180AXX
|
5V/36A
|
180W
|
|
V180BXX
|
12V/15A
|
180W
|
|
V180CXX
|
15V/12A
|
180W
|
|
V180DXX
|
24V/7.5A
|
180W
|
|
V250AXX
|
5V/50A
|
250W
|
|
V250BXX
|
12V/21A
|
250W
|
|
V250CXX
|
15V/17A
|
250W
|
|
V250DXX
|
24V/11A
|
250W
|
|
V270AXX
|
5V/54A
|
270W
|
|
V270BXX
|
12V/22A
|
270W
|
|
V270CXX
|
15V/18A
|
270W
|
|
V270DXX
|
24V/12A
|
270W
|
|
To
order, replace "XX" in model number with sum
of Option Codes desired.
Other
voltages, e.g. 2V, 3.3V, 28V, and 48V available on special
order.
|
|
|
|
|
V
Singles
|
|
Model
|
Output
|
Max
Power
|
|
V360AXX
|
5V/72A
|
360W
|
|
V360BXX
|
12V/30A
|
360W
|
|
V360CXX
|
15V/24A
|
360W
|
|
V360DXX
|
24V/15A
|
360W
|
|
V501AXX
|
5V/100A
|
500W
|
|
V501BXX
|
12V/42A
|
500W
|
|
V501CXX
|
15V/33A
|
500W
|
|
V501DXX
|
24V/21A
|
500W
|
|
V601AXX
|
5V/120A
|
600W
|
|
V601BXX
|
12V/50A
|
600W
|
|
V601CXX
|
15V/40A
|
600W
|
|
V601DXX
|
24V/25A
|
600W
|
|
|
Options
|
|
Option
Code
|
Function
|
|
00
|
None
|
|
01
|
OVP protects all auxiliaries
|
|
02
|
Power Fail Monitor
|
|
04
|
Thermal Shutdown
|
|
08
|
Cover
|
|
16
|
Logic inhibit
|
|
To
order, replace "XX" in model number with sum
of Option Codes desired.
|
|
|
| |
|
V
Quads
|
| Model |
Output
1 |
Output
2 |
Output
3 |
Output
4 |
Max
Power |
| V225AXX |
5V/30A |
+12V/6(12)A |
-12V/4A |
-5V/4A |
225W |
| V225BXX |
5V/30A |
+12V/6A |
-12V/4A |
+24V/4(8)A |
225W |
| V225CXX |
5V/30A |
+15V/6(12)A |
-15V/4A |
-5V/4A |
225W |
| V225DXX |
5V/30A |
+15V/6A |
-15V/4A |
+24V/4(8)A |
225W |
| V225EXX |
5V/30A |
+12V/6(12)A |
-12V/4A |
+12V/4A |
225W |
| V325AXX |
5V/45A |
+12V/8(16)A |
-12V/6A |
-5V/4A |
325W |
| V325BXX |
5V/45A |
+12V/8A |
-12V/6A |
+24V/4(8)A |
325W |
| V325CXX |
5V/45A |
+15V/8(16)A |
-15V/6A |
-5V/4A |
325W |
| V325DXX |
5V/45A |
+15V/8A |
-15V/6A |
+24V/4(8)A |
325W |
| V325EXX |
5V/45A |
+12V/8(16)A |
-12V/6A |
+12V/4A |
325W |
|
Important
Notes:
- Numbers in parentheses
are peak ratings for a short duration service such as motor starting.
- Output 1 is floating
and can be either polarity.
- Quads require
10% of maximum power distributed among auxiliary outputs for optimum
performance.
- Outputs can operate
to no load with slight increase in specifications.
- For agency certifications,