M Series
Specifications

Input
90-132 VAC or 180-264 VAC, 47-63 Hz. Strappable.

Emissions
FCC 20780 Part 15. EN 55022, Class A Conducted. EN 61000-3-3, Voltage Fluctuations.

Immunity
EN 61000-4-2, Level 3 Electrostatic Discharge.
EN 61000-4-3, Level 3 Radiated Field.
EN 61000-4-4, Level 3 Electrical Fast Transients.
EN 61000-4-5, Level 3 Surge.
EN 61000-4-6, Level 3 Conducted Field.

Input Surge
34 amps peak from cold start for units under 400 watts, 68 amps for other models.

Efficiency
75% typical.

Holdup Time
20 milliseconds after loss of nominal AC power.

Outputs
See model selection table. Outputs are trim adjustable ±5%.

Output Polarity
All outputs are floating from chassis and each other and can be referenced to each other or ground as required.

Line Regulation
Less than ±0.1% or ±5mV for input changes from nominal to min. or max. rated values.

Load Regulation
±0.2% or ±10mV for load changes from 50% to 0% or 100% of max. rated values.

Minimum Load
Main output requires a 10% minimum load for full output from auxiliaries. Use Option 08 if no minimum load is available. Singles requires no minimum load.

Ripple & Noise
1% or 100 mV, pk.-pk., 20 MHz bandwidth.

Operating temperature
0-70°C. Derate 2.5%/°C above 50°C.

Cooling
A min. of 6 LFS* for models under 400 watts, 10 LFS for others, directed over the unit for full rating. Two test locations on chassis rated for max. temperature of 90°C. For convection ratings consult factory.
*Linear feet/second.

Temperature Coefficient
±0.02%/°C.

Dynamic Response
Peak transient less than ±2% or ±100 mV for a step load change from 75% to 50% or 100% max. Outputs recover within 300 microseconds.

Safety
Units meet UL 1950/60950, CSA 22.2 No. 60950-00, EN 60 950, IEC 950.

Dielectric Withstand
3000 VRMS input to ground.
3000 VRMS input to output.
700 VDC output to ground.

Spacing
5 mm primary to secondary, 2.5 mm to ground.

Leakage Current
0.75 mA at 115 VAC, 60 Hz. input.

Input Undervoltage
Protects against damage from under voltage operation.

Soft Start
Units have soft start feature to protect critical components.

Overvoltage Protection
Standard on all outputs. Latching action.

Reverse Voltage Protection
All outputs are protected up to load ratings.

Overload & Short Circuit
All outputs are protected by foldback current limiting with automatic recovery.

Thermal Shutdown
Circuit cuts off supply in case of local over temperature. Units reset automatically when temperature returns to normal.

Fan Output
Nominal 12 VDC @ 12 watts maximum.

Inhibit
TTL compatible system inhibit provided.

Remote Sensing
On all outputs greater than 75 watts.

Shock
MIL-STD 810-E Method 516.4, Procedure I.

Vibration
MIL-STD 810-E Method 514.4, Category 1 , Procedure I.

Mechanical Dimensions

Case

Watts

H x W x L
1

250W/425W

2.50" x 4.15" x 8.00"
2
400W/500W
2.50" x 5.05" x 9.00"
3
600W/750W
2.50" x 5.20" x 9.63"
4
600W/750W
2.50" x 6.50" x 9.63"*
5
600W/750W
2.50" x 6.00" x 9.63"**
6
1000W
5.00" x 5.05" x 10.40"
7

1500W

5.00" x 5.20" x 11.00"
*Configurations 40 and 50 only.
**Option 32 only.

OPTIONS

Power Fail Monitor (Code 01)
Optional circuit provides isolated TTL and VME compatible ACFAIL signal providing 4 milliseconds warning before main output drops by 5% after an input failure.

Auto Ranger (Code 02)
Optional circuit provides automatic operation at specified input ranges without strapping.

Zero Preload (Code 08)
Optional circuit removes need for preload on main output. Available for mains up to 500 watts.

End Fan Cover (Code 32)
Optional cover with brushless DC ball bearing end fan which provides the required air flow for full rating of Moduflex® power supplies.

Top Fan Cover (Code 64)
Same as above with fan cover mounted on top of the power supply.

*Specifications subject to change without notice.


 