Description
The LE Series is part of Deltron’s SlimLine group of 1U high power supplies. This series of single output self-cooled models is rated at 300 watts, with each unit measuring 1.58”H x 2.10”W x 11.32”L. Uniquely packaged and highly compact, LE Series modules fit a wide range of industrial, telecom and computer networking applications. These hot pluggable units can be paralleled for additional power or used in combination with other models to meet multiple output requirements. When used in Deltron’s RA30A racking system, as many as 6 LE Series units can be mounted in a 1U high rack space, providing up to 1800 watts.
Designed to meet applicable NEBS standards, units feature a proven topology coupled with excellent thermal management to achieve outstanding performance and safety. DC Good feature provides logic signal for monitoring power supply status. All models are available with redundancy option for parallel or N+1 hot pluggable applications. Low voltage models include N channel ultra low drop Or-ing circuit to maintain power supply efficiency.
LE
Series Rack System
The RA30A 1U high, 19”-wide racking system is available for paralleling or N+1 redundant systems. The 1.75”-high by 12.0”-deep rack can accommodate six LE Series power supplies, providing up to 1800 watts. Racks include a top cover for added strength and protection.
Each
power supply plugs into the backplane and is securely held in place
by removable front panels. Individual output and signal connections
are made via rear accessible Euro-style terminals and headers. Two 3-terminal
Euro-style input connectors are provided, one for each half of the rack.
Racks are designed to accept either EIA or Bellcore NEBS mounting and
heavy-duty solid-bearing slides.
|
 |
Features
- 8 watts per cubic inch
- 80% typical efficiency
- 1U high - SlimLine Package
- Hot Pluggable
- Power Factor
Corrected
- EN 61000-3-2
compliant
- Universal Input
- UL, CSA, TÜV
(IEC,EN)
- FCC, CISPR Class
B EMI
- IEC, EN Immunity
- Standard features
include:
Integral
ball bearing fan
DC
Good Signal
Inhibit
capability
OVP
on all models
Overload
and short circuit protection
Reverse
voltage protection
- Options and Accessories
include:
Redundancy
via ultra low drop Or-ing
circuit with droop current share
Hi-Temp and Fan Fail signals
Nylon
slides
1U
high racking system
|
300 Watt Models |
|
Output |
Model |
|
1.8V @ 56A |
LE1.8-56-YY |
|
2.5V @ 56A |
LE2.5-56-YY |
|
3.3V @ 56A |
LE3.3-56-YY |
|
5V @ 56A |
LE5-56-YY |
|
12V @ 25A |
LE12-25-YY |
|
24V @ 12.5A |
LE24-12.5-YY |
|
48V @ 6.3A |
LE48-6.3-YY |
|
|
400 Watt Models |
|
Output |
Model |
|
12V @ 33A |
LE12-33-YY |
|
24V @ 16.7A |
LE24-16.7-YY |
|
48V @ 8.3A |
LE48-8.3-YY |
|
Other ratings
available on special order.
Replace the YY with the sum of the Option Codes below.
|
Options
|
|
Code
|
Function
|
|
00
|
None
|
|
01
|
Redundancy
|
|
02
|
Nylon
Slides
|
|
04
|
Hi-Temp and Fan Fail
|
|
08
|
Field
Terminations
|
|
|