FS and FT Series
Specifications

Input
90-264 VAC, 47-63 Hz.

Power Factor
0.95 typical.

Emissions
EN 55022/CISPR 22, Class B Conducted. EN 61000-3-2, Harmonics. EN 61000-3-3, Voltage Fluctuations.

Immunity
EN 61000-4-2, Level 3 Electrostatic Discharge. EN 61000-4-3, Level 3 Radiated Field. EN 61000-4-4, Level 3 Electrical Fast Transients. EN 61000-4-5, Level 3 Surge. EN 61000-4-6, Level 3 Conducted Field.

Input Surge
230 VAC - 38 amps max. 115 VAC - 19 amps max.

Efficiency
75% typical.

Holdup Time
20 milliseconds from loss of nominal AC voltage.

Outputs
Outputs are trim adjustable ±5%.

Output Polarity
All outputs are floating from chassis and each other and can be referenced to each other or ground, as required.

Line Regulation
Less than 0.5% for full line change.

Load Regulation
Less than 1% or 40 mV for full load change.

Minimum Load
None required.

Ripple & Noise
1% or 100 mV, pk.-pk., 20 MHz bandwidth.

Operating temperature
0-70°C. Derate 2.5%/°C above 50°C.

Cooling
A minimum of 10 linear feet per second is required, directed through the unit for full rating. Two test locations on chassis rated for maximum temperature of 90°C. The 600, 750 and 1000 watt models include built-in ball bearing fans.

Temperature Coefficient
±0.02%/°C typical.

Dynamic Response
Peak transient less than ±2% or ±100 mV for a step load change from 75% to 50% or 100% max. Outputs recover within 300 microseconds.

Safety
Certified to UL 1950/60950, CSA 22.2 No. 60950-00, EN 60 950.

Isolation
Conforms to safety agency standards.

Input Undervoltage
Protects against damage from under voltage operation.

Soft Start
Units have soft start feature to protect critical components.

Overvoltage Protection
Standard on all outputs. Latching action.

Reverse Voltage Protection
All outputs are protected up to 100% load ratings.

Overload & Short Circuit
All outputs are protected by foldback current limiting with automatic recovery.

Thermal Shutdown
Circuit cuts off supply in case of local over temperature. Units reset automatically when temperature returns to normal.

Fan Output
Nominal 12 VDC @ 12 watts maximum.

Inhibit
TTL compatible system inhibit provided.

Remote Sensing
On all outputs greater than 75 watts.

Shock & Vibration
Shock per MIL-STD 810-E Method 516.4, Procedure I. Vibration per MIL-STD 810-E Method 514.4, Category 1, Procedure I.

Mechanical Dimensions

Case
Series

Watts

H x W x L
1
FT

400W

2.50" x 4.93" x 8.00"
1
FT
500W
2.50" x 4.93" x 8.00"
2
FT
600W
2.56" x 5.08" x 10.03"
3
FS
600W
2.56" x 5.08" x 11.00"
4
FT
750W
2.56" x 5.08" x 10.03"
5
FS
750W
2.56" x 5.08" x 11.63"
6
FS

1000W

2.56" x 7.13" x 11.63"

Warranty
Deltron 2 year Standard Warranty on parts and labor.

OPTIONS

Power Fail Monitor (Code 01)
Optional circuit provides isolated TTL and VME compatible ACFAIL signal providing 4 milliseconds warning before main output drops by 5% after an input failure.

Class B Filter (Code 16)
Included filter to meet EN 55022/CISPR 22, Class B Conducted.

End Fan Cover (Code 32)
Optional cover with brushless DC ball bearing fan which provides the required air flow for full rating of Moduflex® power supplies.

Top Fan Cover (Code 64)
Same as above, with fan cover mounted on top of the power supply.

Droop Current Share
Wireless droop current share is available upon request for parallel or N+1 redundant operation. Contact factory for details.

*Specifications subject to change without notice.

 