| Input
36 - 75 VDC.
Emissions
GR-1089-CORE, Conducted Battery Noise.
Immunity
EN 61000-4-2, Level 3 Electrostatic
Discharge.
EN 61000-4-4, Level 3 Electrical Fast Transients.
EN 61000-4-5, Level 3 Surge.
Input
Surge
80 amps peak from cold start. Units meet ETS300, 386-1, ETSI.
Efficiency
75% typical.
Outputs
See model selection table. Outputs are trim adjustable ±5%.
Output
Polarity
Output is floating from chassis and can be referenced
to ground as required.
Line
Regulation
Less than ±0.5% for full input change.
Load
Regulation
±0.5% or ±10mV for load changes from 50%
to 0% or 100% of max. When redundancy option 01 is specified,
load regulation is 3%, which includes lossless, programmed
current share droop.
Minimum
Load
None required.
Ripple
& Noise
1% or 50mV, pk.-pk. whichever is greater,
20 MHz bandwidth.
Operating
temperature
0-70°C. Derate 2.5%/°C above 50°C.
Cooling
Forced
air cooling with built in fan.
Temperature
Coefficient
±0.02%/°C typical.
Recovery
Time
500 microseconds typical for a step load
change from 50% to 25% or 75%.
Safety
Units meet UL 60950-1,
CSA 22.2 No. 60950-1, EN 60950.
Isolation
Conforms to safety agency standards.
Input
Undervoltage
Protects against damage for undervoltage operation.
Reverse Input Protection
Protects against reverse polarity applied to input. Unit automatically resets when proper input applied.
Soft
Start
Units have soft start feature to protect critical
components.
Overvoltage Protection
Standard on all models.
|
Overload & Short Circuit
Output protected by duty cycle current foldback
circuit with automatic recovery when overload is removed.
Reverse Voltage Protection
Standard on output.
Thermal
Shutdown
Circuit cuts off supply in case of local over
temperature. Units reset automatically when temperature
returns to normal.
DC
Good
Standard circuit provides TTL compatible open
collector Output Fail signal referenced to the common
pin when the output drops by 10% or more.
Inhibit
TTL compatible system inhibit provided.
Enable
Enable pin must be shorted to Common for proper
operation.
Remote
Sensing
Standard on output.
Shock & Vibration
Shock per MIL-STD 810-E Method
516.4, Procedure I. Vibration per MIL-STD 810-E Method 514.4,
Category 1, Procedure I.
Mechanical
Chassis dimensions are 1.58" H x 1.86"
W x
11.32" L.
Connections
Connections via Positronic connector. Option
08 allows connection to power supply via screw terminals
and 8 pin header.
Warranty
Deltron's 2 year Standard Warranty applies.
OPTIONS :
Redundancy
(Code
01)
Redundant operation with either Or-ing diode for higher
voltage models or ultra low drop N channel Or-ing circuit
in low voltage models coupled with wireless droop current
sharing for use as a hot pluggable N+1 redundant system.
Nylon
Slides
(Code 02)
Power supply chassis mounted slides provide ease of
pluggability for use with Deltron Model RA20A or equivalent
racking system.
Hi-Temp & Fan Fail (Code 04)
Hi-Temp: TTL compatible logic signal provides warning when unit approaches thermal shutdown.
Fan Fail: TTL compatible logic signal provides warning when fan speed is inadequate to cool unit.
Field
Terminations (Code
08)
Provides an alternative to Positronic hot pluggable
interface allowing customer to connect to power supply via
screw terminals and 8 pin header. Includes mating connector
for the header. Minimum order 25 pieces.
LC-1
Mating connector kit consisting of Positronic PCIC right
angle board mount connector.
|